Way back our friendly building inspector (he really is friendly and helpful) told us he wanted us to bring in outside air to the furnace room and put in 20" wall openings, one high and one low, both to the office area and to the laundry room. To fulfill the outside air requirement, we put up an insulated 6" flexible tube going from the outside to the furnace room. Of course, we did this a while ago before the ceiling drywall was up. Now the room and the house "breathe" freely.
Just yesterday I got to putting in the wall openings for room ventilation. These are just holes cut in the partition wall with sidewall grilles to make it look nice.
All of this is simply to make sure the furnace and water heater in the room have enough oxygen for combustion (they are both natural gas). They call this combustion air. Without enough combustion air there can be a buildup of carbon monoxide, and that is never good - especially in a house. Building code has calculations for the square inches required for openings to the room based on the size of the room (cubic feet) and on the total BTUs of the appliances in the room.
Of course, every little project seems to have its own snafu. The last grille I was going to put on was missing the packet of screws needed to attach the grille. I have screws but these have a white head to make them less visible. So, I had to drive back up to The Home Depot for a quick exchange.